SurgeX SEQ-1U : Programmable Sequencer Surge
Eliminator - 20A/120V - 1RU
The SurgeX SEQ-1U is a 120V/20Amp three-bank AC power
sequencer incorporating SurgeX Advanced Series Mode power conditioning
and surge elimination. Rated A-1-1, the highest standard of the Federal
Commercial Item Description for Endurance.
SurgeX Sequencers provide the sequencing parameters, conditioning, shutdown
thresholds, and surge protection needed to safeguard audio, video, broadcast,
and computer equipment. SurgeX Sequencers have robust management features
and are extremely easy to install, program, and use. They include always-on
receptacles and programmable banks. SurgeX Sequencers feature one "virtual"
bank for controlling remote units, allowing for infinitely expanding distribution
schemes. SurgeX Sequencers also includes an LCD screen.SurgeX Sequencers
are engineered with Advanced Series Mode® surge elimination technology
to provide top-of-the-line protection. Superior to conventional MOV circuitry
or MOV-Hybrid designs, SurgeX Sequencers completely eliminate surge energy
up to 6,000 volts without producing harmful side effects such as ground
contamination or common-mode disturbances. Completely non-sacrificial
and never needing reset, they provide the most reliable protection available.
SurgeX Sequencers also feature both common mode and normal mode impedance
tolerant EMI/RFI filtering, SurgeX ICE (Inrush current elimination), and
CouVS (Catastrophic over/under Voltage shutdown) for a complete power
conditioning solution. |
SurgeX SEQ-1U
Features: |
- Unsurpassed SurgeX Advanced Series Mode surge
elimination
- SurgeX Impedance Tolerant EMI/RFI Filtering
- SurgeX ICE Inrush Current Elimination
- All-time delays and functions easily programmed
fron the front panel
- Bank "C" can be configured as "Always-On."
- Two or more units can be ganged or cascaded together
for larger systems
- Programmable auxiliary relay output can be used
to control other SurgeX products
- Programmable 12 V DC output can be used to control
other SurgeX products or drive LED's.
- Auxiliary relay or 12 V DC output can be programmed
to provide confirmation feedback
- Built-In AC Voltmeter
- Seperate over-ride input can be used to force
unit "off" or "on."
- Optional password can be used to prevent unauthorized
access to set-up information
- Adjustable under-voltage and over-voltage shut-down.
- Optional restore after power failure feature
- Setup stored in nonvolatile memory
- Three sequenced banks receptacles; two always-on
receptacles
- 8 Outlets (3-Duplex Banks A thru C and 1 Always
On Duplex)
- LCD screen
|
SurgeX SEQ-1U
Includes: |
|
- 1 x Warranty Card
- 1 x Owner's Manual
|
|
Definitions: |
|
Advanced Series Mode:
Patented surge protection technology that eliminates surge energy and
without producing ground-wire contamination or common-mode disturbances.
CouVS: Catastrophic Over-Under
Voltage Shutdown – Protects equipment from harmful spikes or dips
in voltage
SurgeX ICE: Inrush Current
Elimination Filter – Resolves inrush current problems for high
ampacity multi-component systems.
EMI/RFI Filter: EMI -
Electro-Magnetic Interferance RFI - Radio Frequency Interferance
|
Videos: |
|
For questions please call us at (866)
460-2569. Thank you!
|
For questions please call us at (866) 460-2569. Thank you!
|
SurgeX SEQ-1U General Specifications:
Load Rating: |
....... |
20 Amps at 120V |
Max. Load
Inrush: |
....... |
1400 Joules total during power up |
Surge
Let Through: |
....... |
0 Volts at 6,000 Volt Surge |
UL
1449: |
....... |
Adjunct Classification Results: 1000 surges,
6000 volts, 3000 amps, B3 pulse; Measured suppressed voltage: 170 volts;
no failures |
Federal
Guidelines |
....... |
Grade A, Class 1, Mode 1 (CID A-A-55818) |
EMI/RFI
Filter [50 Ohm Load]: |
....... |
[Normal Mode] >30dB 100kHz - 50 MHz
[Common Mode] >20dB 1 MHz - 50 MHz |
Under
Voltage Auto-Shutdown: |
....... |
Adjustable from 90V - 110V |
Over Voltage
Auto-Shutdown: |
....... |
Adjustable from 130V - 150V |
Maximum
Applied Surge Voltage: |
....... |
6,000 Volts |
Maximum Applied
Surge Current: |
....... |
Unlimited, due to current limiting |
Maximum Applied Surge
Energy: |
....... |
Unlimited, due to current limiting |
Endurance: |
....... |
1 kV>500,000; 3 kV>10,000; 6 kV>1,000
(C62.41-1991) Cat B3 Pulses |
Control
Inputs: |
....... |
Momentary Switch, Latching Switch, Contact Closure
or 5-30 Vdc |
Input
Control Current: |
....... |
3 mA |
DC Voltage
Output: |
....... |
12 Vdc, 40 mA maximum load |
Auxillary
Relay Contact Rating: |
....... |
30V DC at 1A |
Contact
Closure Max. Resistance: |
....... |
40 mA |
12
V DC Output Max Current: |
....... |
100 Ohms |
Delay
Times: |
....... |
1 – 40 seconds in 1 second increments |
Dimensions: |
....... |
1.75" H x 19.0" W x 12.25" D
(4.4 x 48.3 x 31.0 cm) |
Weight: |
....... |
13 lbs (5.9 kg) |
Temperature
Range: |
....... |
5 Deg to 35 Deg C |
Humidity Range: |
....... |
5% to 95% R.H. Non-Condensing |
Agency
Listings: |
....... |
UL 1449 3rd Edition
UL 1283 5th Edition
CSA C22.2 No.8-M1986 (R2008) (Pending) |